Here you can find the exhibitors of the EMV 2025. The exhibitor list for 2026 is expected to be available from fall 2025.
ESA1 set Emission Development System
Description
The ESA1 is a system of EMC tools for measuring the interference of assemblies and devices. The CS-ESA software allows the developer to quickly and comprehensively suppress interference affecting the DUT. Interference measurements taken during the development stage with ESA1 are proportional to the results from far-field measurements or from measurements with artificial networks. With the ESA1 tools disturbance sources can be localized, effects can be detected, and EMC measures individually determined. The effects of improvements implemented by ESA1 are proportional to the results from far-field measurements. ESA1 is designed for use at the developer’s working place.
Scope of delivery
- 1xCS-ESA set, ChipScan-ESA Software / USB
- 1xDongle, Licence Dongle
- 1xHFW 21, RF Current Transformer
- 1xHFA 21, RF Bypass
- 1xZ23-1 set, Shielding Tent (900 x 500x 400) mm
- 1xPA 203 BNC, Preamplifier 100 kHz up to 3 GHz
- 1xRF-B 0.3-3, H-Field Probe mini 30 MHz up to 3 GHz
- 1xRF-B 3-2, H-Field Probe 30 MHz up to 3 GHz
- 1xRF-E 02, E-Field Probe 30 MHz up to 1.5 GHz
- 1xRF-E 05, E-Field Probe 30 MHz up to 3 GHz
- 1xRF-E 10, E-Field Probe 30 MHz up to 3 GHz
- 1xRF-R 0.3-3, H-Field Probe mini 30 MHz up to 3 GHz
- 1xRF-R 3-2, H-Field Probe 30 MHz up to 3 GHz
- 1xRF-R 50-1, H-Field Probe 30 MHz up to 3 GHz
- 1xRF-R 400-1, H-Field Probe 30 MHz up to 3 GHz
- 1xRF-U 2.5-2, H-Field Probe 30 MHz up to 3 GHz
- 1xRF-U 5-2, H-Field Probe 30 MHz up to 3 GHz
- 1xESA1 acc, Accessories
- 1x ESA1 case, System case
- 1x ESA1 m, User Manual
Technical parameters
HFW 21 RF Current Transformer
Frequency range 100 kHz - 1 GHz
Continuous power rating
Current 10 A
Dielectric strength 50 V
Sizes (L x W x H) (135 x 32 x 28) mm
HFA 21 RF Bypass
Capacitances 10 pF ... 100 nF
Dielectric strength 50 V
Shielding tent (900x500x400 mm)
Attenuated shielding 45 dB - 50 dB / 30 MHz - 1GHz
Sizes (L x W x H) (900 x 500 x 400) mm
Weight 12 kg
Near Field Probes
Frequency range 30 MHz - 3 GHz
CS-ESA software
Operating system Windows XP/Vista/7 (latest service packs)
PA 203 preamplifier
Frequency range 100 kHz - 3 GHz
Amplification 20 dB
Supply voltage 12 V DC
Current input 50 mA
Max. input power +13 dBm